molecular devices spectramax 190. Equipped with advanced technology that provides flexibility, sensitivity, and convenience for a wide range of assays such as ELISA, microbial growth, and. molecular devices spectramax 190

 
 Equipped with advanced technology that provides flexibility, sensitivity, and convenience for a wide range of assays such as ELISA, microbial growth, andmolecular devices spectramax 190  Free shipping

Molecular Devices Spectramax 190 Plate Reader used + details. Finally, the prepared 96-well cell plate was placed in a Molecular Devices Spectramax 190 full-wavelength microplate reader (Molecular Devices LLC, San Jose, CA, USA) to carry out the dynamic growth experiment. $2,350. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax. • DNA quantitation • Molecular biology • ELISAs • Pharmacology Accurate measurements The SpectraMax 190 reader is the tool for DNA analysis. Community forums for Molecular Devices - SpectraMax 340PC384 Microplate Reader relating to Fatal Error 401 on LabWrench. Molecular Devices SpectraMax PLUS 384 Spectrophotometer System-New ABs1 Performance Testing August 2021. com. Select Update Driver. In the presence of endotoxin, activated rFC will cleave a fluorogenic substrate, causing an increase in fluorescent signal (Figure 1B. Application Area: JAK-STAT signaling, dual-luciferase assays, nanoparticles, spectral scans. Transfected cells were imaged on the SpectraMax MiniMax 300 Imaging Cytometer. SpectraMax 190 Molecular Devices SpectraMax 190 Manuals Manuals and User Guides for Molecular Devices SpectraMax 190. Extended linear dynamic range. The SpectraMax iD5 reader uses the HTRF detection system, which includes an Enhanced TRF Module and filters for excitation and emission. When the user applies a set temperature of 37°C, the top is heated to 37. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. 迅速な測定のための8チャンネル読み取りヘッドを備え、特許取得済みPathCheck ® センサーを搭載していま. Data from multiple wave-lengths can be acquired during a single reading, if desired, and differentFormerly known as the µMax, Molecular Devices’ unique SpectraDrop™ Micro-Volume Microplate offers the highest throughput solution for low volume measurement available on the market. Our microplate readers are the industry’s most cited instruments and have empowered life science researchers to advance protein and cell biology, breaking the barriers to novel, landmark discoveries. Add to Cart. The PathCheck sensor can extend the instrument linearity by a factorManufacturer Device; ABSORBANCE, MICROPLATE READING: BioTek: PowerWave HT Microplate Spectrophotometer: Molecular Devices: EMax Plus: SpectraMax 190: SpectraMax 340PC384The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Minimize sample volume while retaining sensitivity with the SpectraDrop Micro-Volume Microplate. 28025-013 used in original study:. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate. 0A Sunnyvale, CA Made in USAThe SpectraMax® 340PC384 Reader from Molecular Devices provides everything needed to measure absorbance in the visible range, including temperature control, a robotics-compatible interface and SoftMax® Pro Data Acquisition and Analysis Software. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers Operator’s Manual — 0112-0115 Rev. Perkin Elmer Wallac 1420 Victor2 Microplate Reader. 00 0 bids 2d 20h. 8: 0. The PathCheck sensor can extend the instrument linearity by a factor • DNA quantitation • Molecular biology • ELISAs • Pharmacology Accurate measurements The SpectraMax 190 reader is the tool for DNA analysis. Page 1 ® SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0049 Rev. Both cell density and GFP signals were recorded over a time course using the Workflow Editor acquisition function. Table1-1 SpectraMax ® Multi-Mode Microplate Readers and Applicable Modes Modes SpectraMax M3 SpectraMax M4 SpectraMax M5. Perkin Elmer Wallac 1420 Victor2 Microplate Reader. Photometric Range. The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in. By measuring optical pathlength, it eliminates the last major distinction between microplate readers and spectrophotometers. Microplate Readers. The chamber contains springs that position the cuvette in the proper alignment for a read. Compact design. ¨ Read - For the SpectraMax 190 and SpectraMax 340PC384, press to initiate the plate read when you operate the instrument in stand alone mode. SpectraMax 190 Absorbance Microplate Reader by Molecular Devices®. To update the driver. These robust readers have been placed in labs from Antarctica to. Molecular Devices SpectraMax 340PC384 Microplate Reader $ 4,000. 9. Category 2 and 3 microplate readers use gradient heating as well. on the SpectraMax Multi-Mode Microp late Readers by issuing a single command in SoftMax ® Pro Software, Molecular Devices leading microplate data acquisition and analysis software platform. Add to Cart. SpectraMax i3x 微孔板读板机, Molecular Devices (Cat# i3X) 96 孔白色底透板, Costar (Cat# 3903. When the user applies a set temperature of 37°C, the top is heated to 37. The drawing shows a standard microplate of 15 mm height covered with a lid. Find regional support. 2018 Molecular Devices SpectraMax iD5 Microplate Reader- Certified with Warranty. Call 1-800-745-2710. SpectraMax® Plus 384. spr SpectraMax M2 M2e M3 M4 M5 M5e. The microplate. Stat Fax 2100 Microplate Reader. SpectraMax QuickDrop Micro-Volume Spectrophotometer. Spectramax® id3 multi-mode microplate reader, molecular devicesMolecular devices showcases spectramax I3x spectramax pdfSpectramax® i3:. We have 1 Molecular Devices SpectraMax. 1. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. Supplier: Molecular Devices. IMAP ® Technology from Molecular Devices enables rapid, homogeneous, and non-radioactive assay of kinases, phosphatases, and phosphodiesterases and is suited for both assay development and high-throughput screening. When the correct COM port is selected, the. Category 2 and 3 microplate readers use gradient heating as well. The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget-friendly solution with three modes of detection for UV-Vis absorbance, fluorescence, and luminescence. It may be named "Pothos". To perform operations that require data you must be ableBelow is the list of Molecular Devices microplate readers and liquid handling instruments that are of out-of-production and are now considered obsolete. D. 2, 2022 – Molecular Devices announced today the launch of the ValitaCell IgG titer assay, ValitaTiter, available for global distribution. It has dual scanning monochromators that allow for 1 nm increment selection over the wavelength range of 250 - 850 nm. Details. Wavelength(s) 190 to 1100 nm; Quantity EA; Dimensions (WxDxH) 11 x 16. Tecan Infinite 200 Microplate Reader. Double-click the unknown device with the yellow warning icon. Molecular Devices Spectramax 190 Plate Reader used + details. Simplify and expedite experiments with SoftMax Pro. 8: 0. Conclusion. Add 10 μL 10 mM catechol to each well that will contain a reaction. 7°C (gradient heating design). Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. One complete solution With available options such as the SpectraMax® MiniMax™ 300 Imaging Cytometer, ScanLater™ Western Blot cartridge, reagents optimized for high performance, and the industry-leading data acquisition and analysis tool SoftMax Pro, the SpectraMax i3 x Detection Platform is the total solution for all your research needs. Supplier: Molecular Devices. The . 00 ADD TO CART. The SpectraMax ® Plus 384 Microplate Reader gives you walk-up convenience for both standard spectrophotometer and microplate reader applications on. Jouko Lukkarinen Asiantuntija, Virtaussytometria +358 40 660 2555 jouko. 9000-0756. SpectraDrop Micro-Volume Refills, 24-Well Bottom Slides. Technical specifications Performance specifications Cross-talk < 3 x 10-5 (96-well) Read modesCompatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. ; Page 2 Molecular Devices equipment, software, reagents, and consumables. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. SpectraMax® 190. Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. Then 150 μL of DMSO was added to dissolve the formazan crystal and the absorbance was measured at 570 nm at UV-Vis plate reader (Molecular Devices Spectramax 190). GFP expression imaged on the cytometer. 0 out of 5 $ 8,999 $ 8,795. 0 out of 5 $ 4,499. This technical note demonstrates validation of the SpectraMax® i3x Multi-Mode Microplate Reader for NanoBRET™ assays. SpectraMax readers support page; Analyst and FlexStation reader support page; Plate handlers and washers support page; We are continuously adding material to the knowledge base. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. Description 1. SpectraMax® Microplate Reader Suite of Products Knowledge Base. Currently we have over 300 Windows 7/10 compatible instrument drivers to control equipment from 147 manufacturers, meaning that we are likely to have your instrument already in our library. Wavelength Accuracy: < ± 2. The multi-channel design truly mimics a dual-beam spectrophotometer. Electrophoresis, Microplate Readers Lonza 384 Nucleofector System. This user guide provides detailed instructions, troubleshooting tips and technical specifications for these instruments. SpectraMax ® ABS / ABS Plus吸光マイクロプレートリーダーは、ELISA、微生物増殖、タンパク質定量などの様々なアッセイを容易に、また、迅速に行えます。. + details. See the installation guide or user guide. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. We would like to show you a description here but the site won’t allow us. The SpectraMax® i3 Platform from Molecular Devices® is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. Repair or replacement as provided under this warranty is the exclusive remedy to the purchaser (the “Buyer”). iD5. 9. Model: SpectraMax 190. 190: G1–G3. SpectraMax i3x reader measures absorbance, fluorescence, & luminescence with user-upgradeable application including western blot imaging, AlphaScreen, fast kinetics along with injectors plus additional detection modes. 20. We would like to show you a description here but the site won’t allow us. The Gemini XPS Reader has dual monochromators that allow users to utilize new and novel dyes without purchasing expensive filter sets. Capable of detecting DNA down to 25 ng per well, this model gives users. Please Inquire. no. The . and California) 190. Page 18 VersaMax. Supplier: Molecular Devices. We conducted the experiments at three time points with five repetitions for each time. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. Awareness Technology, Inc. Microplate Readers. A: percent GFP-positive cells calculated using the classification feature in the software. 는. ability to detect 16 ng/well of DNA and to quantitate 50 ng of . The SpectraMax Plus 384 Microplate Spectrophotometer is a versatile and reliable instrument that can measure absorbance in the UV and visible range. Select the Driver tab. D 1 1. Published Dec 16, 2020 | Updated Dec 06, 2021. Overview. ATG ensures your Molecular Devices microplate readers and washers run smoothly. Rapid, accurate DNA, RNA, and protein quantitation in a one-touch, full-spectrum micro-volume absorbance reader. Please Inquire Used. 0: 200. Learn how to use the SpectraTest ABS2 Validation Plate, a convenient and reliable tool for verifying the performance of your absorbance microplate reader. Your equipment should rely on ATG. Monochromator, tunable 1. Molecular Devices SpectraMax 190 Microplate Absorbance Spectrophotometer. Setup Guide on the Molecular Devices SpectraMax® M5/M5e Microplate Reader Have a question? Contact our Technical Support Team NA: 800-955-6288 or INTL: 760-603-7200 ext. 1. 5577. The opaque walls prevent stray light from being detected from neighbouring. 1. item 3 Molecular Devices SpectraMax 190. begin reading microplates with seven mouse clicks. UV/Vis/Fluorescence Microplate Reader 1 Molecular Devices SpectraMax iD3 2017 Wold 210 UV/VIS/NIR dual monochromator spectrophotometer 1 Perkin-Elmer Lambda 900 2003, software update 2021 ISEC 270After 4 days 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS; Promega catalog no. Perkin Elmer Wallac 1420 Victor2 Microplate Reader. UV/Vis 96-well clear plates for use on Molecular Devices Spectramax 190: First-strand cDNA synthesis kit: cDNA synthesis: Sigma–Aldrich: GE27-9261-01: Replaces Invitrogen cat. Instrument pricing. S. To contact technical support by phone in the. The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. 1. The 1/absorptivity value for double stranded DNA at 260 nm is commonly assumed. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-Title: SpectraMax i Series Multi-Mode Microplate Readers | Molecular Devices Author: Molecular Devices Subject: SpectraMax i Series offer the ideal solution for any application whether you are looking for an intuitive, easy-to-use reader, multi-user lab, or an upgradeable system that can adapt to support your lab s new projects. Plate stacker and robot integration The SpectraMax 190 reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. 00 0 bids 2d 20h. 9 in. solution for validating the performance of the SpectraMax 190 . 7°C and the bottom to 36. The SpectraMax 190 reader can be integrated with Molecular Devices’ StakMax Microplate Stacker in a matter of minutes and. For more information, please visit us at Devices SpectraMax 190 Microplate Reader. 1. SpectraMaxPlus384,190,340PC384,andVersaMaxInstallationGuide 2 5308727A. ability to detect 16 ng/well of DNA and to quantitate 50 ng of . At that point halfway up the maximum transmittance value, the total width (nm) of the transmitted band is the number being expressed with the instrument bandwidth. This reader also makes use of a unique temperature-independent methodology for path length correction. The optical system of the SpectraMax 190 Microplate Reader is built around a monochromator, which allows for selection of up to six wavelengths at a time for absorbance detection in the UV-visible wavelength range (190 nm - 850 nm). Despite recent advances in structural determination of individual proteins, elucidating the 3-dimensional architecture of large, multiprotein complexes remains challenging, partly because of issues related to structural integrity during purification. UV Qualification, using NIST traceable standards, is now available for SpectraMax 190, Plus 384 and the M Series (M2/M3/M4/M5/M5e) Parameters that are checked during the UV Qualification are: Wavelength accuracy. Pipet 60 µL diluent to each assay well. The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. Temperature control. The multi-channel design truly mimics a dual-beam spectrophotometer. Both readers feature an 8-channel read head for fast reads and a subset feature, the temperature independent PathCheck sensor that. Enter this value into the Data Reduction dialog box (see Figure 2). Molecular Devices SpectraMax M5 Multi-mode Plate Reader 6. 312 gain calibration failed. SpectraDrop High-Throughput Screening (HTS) Kit. Awareness Technology Inc. Typically the system can detect absorbance, luminescence, fluorescence, and even make more specialized fluorescence measurements like time-resolved fluorescence (TRF) and fluorescence polarization (FP). The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. Register to download your free eBook today. SpectraMax 190 SpectraMax 340PC. The Molecular Devices SpectraMAX absorbance microplate readers mimic a dual beam spectrophotometer with a patented multichannel optical design. Molecular Devices Technical Support. Validating the absorbance optical performance of your microplate reader is as simple as reading a plate. HTRF is a versatile TR-FRET technology developed by Cisbio for detecting biomolecular interactions. 0 nm. These robust readers have been placed in labs from. The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. Molecular Devices > SoftMax Pro 6. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and. 7°C (gradient heating design). Pipet 60 µL diluent to each assay well. Narrow bandwidths deliver increased measurement accuracy and linearity over the widest range of assays, including. 1. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Molecular Devices SpectraMax Gemini EM. New drivers take 6 days to write, existing drivers take 2 days to. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- Fluorescence Microplate Reader Comparison Chart. 0200-7027. SpectraMax® Plus 384 provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. ® 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. 635. Your applications, your modes, your choice. This tunable visible absorbance reader is for 96- and 384-well microplates and acquires data in endpoint, kinetic, and spectral scan modes using wavelengths from 340-850 nm, tunable in 1. Category 2 and 3 microplate readers use gradient heating as well. Fluorescence and fluorescence polarization. Discuss DiscussPlus384,340PC384,190,ABS,ABS Plus,VersaMax, FlexStation 3 0200-5060 SpectraTest FL1 FluorescenceValidation Plate. Setting up protocols for screening is user friendly and easy. The calculated LOQ values were 0. 200. User Manuals, Guides and Specifications for your Molecular Devices SpectraMax 190 Measuring Instruments. 8 in. The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Tecan Infinite 200 Microplate Reader. 00. Title:Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0102 Rev. 4 cm. The device powers on and appears to be operational but cannot be connected to SoftMax Pro software. 0200-6262. 2. H1–H3: Set up assay plate . The SpectraMax® M3 Multi-Mode Microplate Reader dual monochromatic optics allows the widest range of applications to be utilized for bioresearch applications all without the need to change filters, and provides three modes of detection in one platform. Multimode Readers Comparison Chart. Wavelength precision. 0200-0729. Integrated stacker option. SpectraMax M2 & SpectraMax M2e Multi-mode Plat e Readers Operator s Manual 0112-0115 Rev. The device powers on and appears to be operational but cannot be connected to SoftMax Pro software. Sunnyvale, CA, February 13, 2013 - Molecular Devices®, market leader in microplate reader technology for over 25 years, has announced today the launch of its SpectraMax® i3 Multi-Mode Detection Platform. Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. Note: Due to the continuous changes in printer technology and printer obsolescence, Molecular Devices does not recommend relying on printing in standalone mode. SpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. The SpectraMax® QuickDrop™ Micro-Volume Spectrophotometer . HEALTH AND SAFETY CONSIDERAIONSMolecular Devices SpectraMax® M5. A = 2 - log 10 (%T). A. Molecular Devices Corporation SPECTRAmax. 2 nm. Table 2. lukkarinen@berner. Gemini EM is a microplate spectrofluorometer from Molecular Devices. The drawing shows a standard microplate of 15 mm height covered with a lid. 0 out of 5 $ 6,499-2%. If there is anything serviceable MD will make you send it in or pay for a service call. 0200-6263. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. $700 USD. industry-leading data acquisition and analysis tool SoftMax Pro, the SpectraMax i3x Detection Platform is the total solution for all your research needs. Spectranet customer portalMolecular Devices Spectramax 190 Plate Reader used + details. Here, we describe validation of the microplate reader with the NanoBRET ™ PPI Control Pair, consisting of the interacting protein partners p53 and MDM2, on the SpectraMax iD5 reader. With optimized reagents and the industryleading data acquisition and analysis tool, SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. Summary of Contents for Molecular Devices SPECTRAmax 340PC. Benchtop scanning fluorometer and integrated fluid transfer workstation (134 pages)The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. H1–H3. Total flavonoids was expressed as hesperidin equivalents (mg of hesperidin × 100 g dry tissue −1 ) through the calibration curve developed with hesperidin. To update the driver. For a higher Which SpectraMax M Series reader do you need? SpectraMax M Series Multi-Mode Microplate Readers 5 Ordering information VWR cat. We would like to show you a description here but the site won’t allow us. item 3 Molecular Devices SpectraMax 190 Microplate Spectrophotometer Molecular Devices SpectraMax 190 Microplate Spectrophotometer . Slide the tip into the nozzle, the slots are labeled 1 and 2 for injector 1 and injector 2. 4 Figures from 1912 PublicationsMolecular Devices SpectraMax 190 Microplate Reader. UV Qualification, using NIST traceable standards, is now available for SpectraMax 190, Plus 384 and the M Series (M2/M3/M4/M5/M5e) Parameters that are checked during the UV Qualification are: Wavelength accuracy. View the Molecular Devices website. 00. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. While they play an important role in generating data from a wide range of. Published Dec 16, 2020 | Updated Dec 16, 2020. Molecular Devices Flourmeteric Imaging Plate Reader FLIPR 384. Keywords:Molecular Devices is ISO 17025 accredited† by American Association of Laboratory Accreditation (A2LA), which requires rigorous outside auditing on a regular basis so that you can be assured of the accuracy of your certificate with respect to NIST and NMI traceable standards. MOLECULAR DEVICE M5. Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser (the “Buyer”). 5039228D 3 Contents SafetyInformation 5 Warnings,Cautions,Notes,andTips 5 Chapter1:Introduction 11 ComputerIntegration 12 Applications 12 Optics 13 PlateControls 13FlexStation® 3 Multi-Mode Microplate Reader. H1–H3: Set up assay plate . D 1 1. 11. a SpectraMax 190 spectrophotometer (Molecular Devices, LLC, Sunnyvale, CA). Measure assay absorbance values quickly with minimal background noise on the SpectraMax iD5 reader. Luminescence. Select Update Driver. When the user applies a set temperature of 37°C, the top is heated to 37. , Tokyo, Japan) was added to each well every 24 h. The multi-channel design truly mimics a dual-beam spectrophotometer. On LabX buyers can find a variety of SpectraMAX models for sale: 190, 384, 340 and the SpectraMAX M series. Note: If you install the SpectraMax MiniMax 300 Imaging Cytometer, do not use this procedure. Table 1. These models can no longer be repaired. Molecular Dynamics Phosphorimager Model 425FSpectraMax 190: Located in the back of lab 302 . Photometric Performance SpectraMax 190 Item Description Wavelength range 190 nm to 850 nm Wavelength selection Monochromator tunable in 1 nm increments Wavelength. The SpectraMax® 190 can read as low as 2μL with the μMax Low Volume Plate. Here, we demonstrate that with Molecular Devices SpectraMax® microplate readers and the Quant-iT PicoGreen assay, users can reliably measure concentrations as low as 50 pg/mL of double-stranded DNA. The . Molecular Devices Subject: The SpectraMax i3x Multi-Mode Microplate Reader has been validated for use with the ValitaTiter and ValitaTiter Plus assays. The SpectraMax® 190 UV-Vis Microplate Spectrophotometer from Molecular Devices is ideal for life science applications, especially DNA analysis. Protein concentrations were calculated using. Let Molecular Devices® and the SpectraMax i3x Multi-Mode Detection Platform power your next landmark discovery. Determine concentration using the Beer-Lambert Law• Molecular Devices SpectraMax 190 (Spectrophotometer) with SoftMax Pro software • Nikon Eclipse TE2000-S (Fluorescent Microscope with digital imaging) with Q-Capture Pro softwareMolecular Spectramax 190 Microplate Reader. SpectraMax ABS ABS Plus Plate washer, Stacker Automation System. Molecular Devices Corporation 1311 Orleans Drive Sunnyvale,. . Bioz Stars score: 86/100, based on 1 PubMed citations. For nearly 30 years, Molecular Devices has provided scientists with tools to expand the boundaries of their research. Because many reagents can be fluorescently labeled, spectrofluorometers are used to detect many biological and chemical processes. used. Products : SoftMax Pro Software, SoftMax Pro GxP Software, CellReporterXpress software, General, Screenworks, pCLAMP/AxoScope, GenePix Pro, MetaXpress. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Stray light. Tailored to your different needs, these assay kits are configured and optimized for Molecular Devices SpectraMax® microplate readers, with preconfigured protocols provided in SoftMax® Pro Software for simplified data acquisition and analysis. It may be named "Pothos". With three modes of detection for full spectrum absorbance, fluorescence and luminescence, the SpectraMax® Mini reader . on the SpectraMax Multi-Mode Microplate Readers by issuing a single command in SoftMax® Pro Software, Molecular Devices’ leading microplate data acquisition and analysis software platform. 3 and higher include optimized reader settings, as well as data analysis, for faster results. . Lamp source is a Xenon flash lamp (1 Joule/flash). Rose Bengal is a photoreactive compound with its absorbance peaks at 258 nm, 519 nm, and 562 nm Citation 33. 5. Fill a clean plate with water. In this article, Biocompare product reviewers share why the Molecular Devices SpectraMax M5 Multi-Mode Microplate Reader is one of the best on the market. Select a kinetic measurement, and set absorbance to 375 nm. Some of the unique features of the SpectraMax Plus 384 Microplate Reader are: Wavelength Range: 190–1000 nm in 1-nm increments190. This assay kit is optimized for SpectraMax microplate readers from Molecular Devices, with a pre-configured protocol provided for customers using Molecular Devices’ SoftMax Pro Software for their data acquisition and analysis. no. 0112-0115J 9 Chapter1:Introduction TheSpectraMax®M3Multi-ModeMicroplateReader,SpectraMax®M4Multi-ModeMicroplate Reader,SpectraMax®M5Multi-ModeMicroplateReader,andSpectraMax®M5eMulti-ModeMolecular Devices SpectraMAX 190 Microplate Reader/Spectrophotometer, Tested. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747. We would like to show you a description here but the site won’t allow us. Select the Driver tab and click Update Driver. 1. Scanning options are endpoint, kinetic, spectral. 2 nm * Wavelength Range 190 – 850 nm * Photometric. Learn how to operate the VersaMax, SpectraMax 340PC384 and SpectraMax 190 Plus384 microplate readers, which offer fast and accurate absorbance measurements for a variety of assays. ) gap between the rear of the instrument and the wall. to 11. Molecular Devices technical support. Step 4. spr * SpectraMax i3(x) SpectraTest ABS2 v1. Each sample has a discrete sample beam and reference beam so that each well is measured directly. Molecular Devices Corporation (the “Seller”) shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, ex-Molecular Devices. Press down on the cuvette chamber lid to open the lid and insert or remove a cuvette. Read Review > >>. polynomial 2nd analysis from the protein standards. 0 mm wide, and heights from 14 mm to 15 mm. Microplate readers from Molecular Devices are designed to provide consistent performance for many years. 6% for the on-board optics (monochromators). On LabX buyers can find. 1. The SpectraMax® Gemini™ XPS Microplate Spectrofluorometer from Molecular Devices® provides a flexible environment to determine the optimal excitation and emission settings for most fluorescent intensity assays. Molecular Devices SpectraMax M2 Microplate Reader with Warranty . and California) Protected by US Patents 4,968,148; 5,112,134; 6,151,111; and 6,188,476 Protected by Canadian Patent 1,305,334Molecular Devices SpectraMax 384 Plus Microplate Reader. 0. Press down on the cuvette chamber lid to open the lid and insert or remove a cuvette. 190 – 1000 nm: Wavelength Selection: Monochromator, turnable in 1. 9 in. 41. This page. 문의하기. The SpectraMax i3x Multi-mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with added functaionlity of modular upgrades for Western Blot, Imaging, and Fast Kinetics with Injectors. Molecular Devices, LLC Subject: SpectraMax ABS and ABS Plus Microplate Readers are a compact and tunable. 1: The SPECTRAmax 190 System The on-board microprocessor calculates and reports the absorbance (or % Transmittance) for each well of a microplate. Minimize sample volume while retaining sensitivity with the SpectraDrop Micro-Volume Microplate. ®This version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. Double-click the unknown device with the yellow warning icon. This document is provided to customers who have purchased Molecular Devices equipment, software, reagents, and consumables to use in the operation of such. The VersaMax and SpectraMax 190 read 96-well microplates. Reads standard cuvettes & 96-384 well plates from 190 to 1000 nm. Plate stacker and robot integration The SpectraMax 190 reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Figure 1. Tumor cells were plated onto 96-well plates (500 cells/well), and 10 µl of Premix WST-1 Cell Proliferation Assay System (Takara Bio Inc. The SpectraMax® 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. Machinery Dimensions: 16 x 24 x 18 IN; Serial Number: 363703713, SMM40479;Streamline BCA-based protein quantitation on the SpectraMax iD5 reader. Microplate spectrophotometer (54 pages) Measuring Instruments Molecular Devices FlexStation II Operator's Manual. 10. 190–1000 nm, which is equivalent to having 510 or 810 free filters, respectively. 0 out of 5 $ 11,499. Get a front row view of your cells. NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time.